The Apera TN480 is a premium version of the TN400 turbidity meter.
The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operating system, simple calibration, and GLP data management.
Apera TN480 uses an infrared light source and 90° scattering method, which is compliant with the ISO 7027 method. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operating system, simple calibration, and GLP data management.
Automatically takes multiple consecutive readings, and calculate the average, minimum and maximum value, as well as displaying each set of data in a brief test report. TruRead is a much better way to determine the true turbidity of your samples, rather than relying on just one reading. It's especially suitable for sample solutions with rapid settling and continuous measurement changes.
200 sets of data storage with USB data output to PC (Windows-based only)
The zero-point calibration and zero-point error reminder functions ensure the high accuracy for low-turbidity (<1 NTU) sample testing
The meter is equipped with a large TFT color screen with plain language and graphic navigation, supporting English, Spanish, and Chinese. Intelligent functions such as automatic calibration, real-time clock display, calibration date check, auto. power off, and low battery reminder are built-in to ensure ease of use.
Specification |
Description |
Measurement Method |
90° scattering measurement, ISO 7027 compliant |
Light Source |
Infrared |
Measuring Range |
0 to 1000 NTU (FNU), automatic range switch 0.01 to 19.99 NTU(FNU) 20.0 to 99.9 NTU(FNU) 100 to 1000 NTU(FNU) |
Accuracy |
≤ ±2% of reading+ stray light |
Repeatability |
≤ ± 1% of reading or 0.02 NTU(FNU) (the greater of the two) |
Resolution |
0.01/0.1/1 NTU (FNU) |
Stray Light |
≤0.02 NTU (FNU) |
Calibration Standard |
AMCO Polymer or Formazin Solution:0, 20, 100, 400 and 800NTU (FNU) |
Detector |
Silicon photovoltaic |
Measuring Mode |
Normal measurement and TruRead measurement |
Data Storage |
200 groups |
Data Output |
USB to PC |
Calibration Record |
Calibration date and time |
Display |
TFT color screen |
Sample Vial |
Φ25×60 mm,high borosilicate glass with lid |
Sample Vial Volume |
18 ml |
Power supply |
3-AAA alkaline batteries |
Working Condition |
Temperature: 0 to 50°C(32°F to 122°F);Relative humidity: 0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation |
Instrument sealing grade |
IP67 |
Certificates |
ISO9001:2015 and CE |
Limited Warranty |
2 years |
Dimension and Weight |
Meter: (90×203×80) mm/385g Test Kit: (310×295×110) mm/1.5kg |